☰ Navigation Tabs
Structure-function insights reveal the human ribosome as a cancer target for antibiotics
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 19000 Reported Resolution (Å) 3.6 Resolution Method FSC 0.143 CUT-OFF Other Details RELION Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol RIGID BODY FIT Refinement Target Maximum likelihood Overall B Value Fitting Procedure Details
Data Acquisition Detector Type FEI FALCON II (4k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 400 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 0.001 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 79000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Gautomatch Gautomatch_v0.50 IMAGE ACQUISITION EPU CTF CORRECTION CTFFIND CTFFIND 4 MODEL FITTING UCSF Chimera FINAL EULER ASSIGNMENT RELION RELION1.4 CLASSIFICATION RELION RELION1.4 MODEL REFINEMENT PHENIX PHENIX1.10
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION Relion