☰ Navigation Tabs
Cryo-EM structure of mTORC1
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 8.468 f_angle_d 1.466 f_chiral_restr 0.064 f_bond_d 0.011 f_plane_restr 0.008
Sample human mTOR complex 1
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 115039 Reported Resolution (Å) 4.4 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C2
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol OTHER Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 8.25
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1500 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 22500 Calibrated Magnification 22500 Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 1.4 IMAGE ACQUISITION UCSFImage4 CTF CORRECTION CTFFIND3 3 MODEL FITTING EMfit INITIAL EULER ASSIGNMENT RELION 1.4 FINAL EULER ASSIGNMENT RELION 1.4 RECONSTRUCTION RELION 1.4 MODEL REFINEMENT PHENIX
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 486584