☰ Navigation Tabs
Electron cryo-microscopy of chikungunya virus in complex with neutralizing antibody Fab CHK265
Sample chikungunya virus in complex with neutralizing antibody Fab CHK265
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument GATAN CRYOPLUNGE 3 Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 5828 Reported Resolution (Å) 16.9 Resolution Method Other Details SUBMISSION BASED ON EXPERIMENTAL DATA FROM EMDB EMD-3144. (DEPOSITION ID: 13751) Refinement Type Symmetry Type POINT Point Symmetry I
Data Acquisition Detector Type GATAN ULTRASCAN 4000 (4k x 4k) Electron Dose (electrons/Å**2) 22
Imaging Experiment 1 Date of Experiment 2015-03-10 Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 1500 Maximum Defocus (nm) 3000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 47000 Calibrated Magnification 78354 Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version RECONSTRUCTION jspr
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details EACH PARTICLE