3J78

Structures of yeast 80S ribosome-tRNA complexes in the rotated and non-rotated conformations (Class I - non-rotated ribosome with 2 tRNAs)


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 3U5B 
experimental modelPDB 3U5C 
experimental modelPDB 3U5D 
experimental modelPDB 3U5E 
experimental modelPDB 3I9B 
experimental modelPDB 3J3B 
Sample
80S ribosome bound to mRNA containing Kozak sequence and to two tRNAs
Sample Components
80S ribosome
transfer RNA
messenger RNA
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK II
Cryogen NameETHANE
Sample Vitrification DetailsPlunged into liquid ethane (FEI VITROBOT MARK II)
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles23163
Reported Resolution (Å)6.3
Resolution MethodFSC 0.143 CUT-OFF
Other Details(Single particle--Applied symmetry: C1)
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3U5B, 3U5C, 3U5D, 3U5E, 3I9B, 3I9B, 3I9B, 3J3B)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Targetcross-correlation
Overall B Value
Fitting Procedure
DetailsREFINEMENT PROTOCOL--rigid body DETAILS--3U5B, 3U5C, 3U5D, and 3U5E were combined prior to fitting. tRNAs and mRNA were modeled using individual tRNA ...REFINEMENT PROTOCOL--rigid body DETAILS--3U5B, 3U5C, 3U5D, and 3U5E were combined prior to fitting. tRNAs and mRNA were modeled using individual tRNAs and mRNA from the crystal structure (3I9B) of the classical-state 70S ribosome. The structure of rpL1 was obtained by homology modeling from PDB ID 3J3B.
Data Acquisition
Detector TypeFEI FALCON I (4k x 4k)
Electron Dose (electrons/Å**2)30
Imaging Experiment1
Date of Experiment2013-01-02
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1159
Maximum Defocus (nm)4844
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS0.01
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification133333
Calibrated Magnification133333
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONCTFFIND3
MODEL FITTINGCNS
MODEL FITTINGUCSF Chimera
RECONSTRUCTIONEMAN2
RECONSTRUCTIONFREALIGN
RECONSTRUCTIONIMAGIC
RECONSTRUCTIONRSAMPLE
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
CTFFIND3, FREALIGN per micrograph