Skip to main content

 38MJ | pdb_000038mj

DDB1delBPB-CRBN (Open) with Iberdo+VVD-105917 -30mins: Composite map and model submission


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 8CVP 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d10.142
f_angle_d0.687
f_chiral_restr0.045
f_plane_restr0.005
f_bond_d0.004
Sample
DDB1delBPB-CRBN+Iberdomide+VVD-105917
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentHOMEMADE PLUNGER
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles2280317
Reported Resolution (Å)2.82
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (8CVP, 8CVP)
Refinement SpaceRECIPROCAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value152.7
Fitting Procedure
Details
Data Acquisition
Detector TypeTFS FALCON 4i (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TALOS ARCTICA
Minimum Defocus (nm)800
Maximum Defocus (nm)1200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification190000
Calibrated Magnification189189
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARCv4.7.0
IMAGE ACQUISITIONEPU3.9.1.8206
CTF CORRECTIONcryoSPARCv4.7.0
MODEL FITTINGCoot0.9.8.96
INITIAL EULER ASSIGNMENTcryoSPARCv4.7.0
FINAL EULER ASSIGNMENTcryoSPARCv4.7.0
CLASSIFICATIONcryoSPARCv4.7.0
RECONSTRUCTIONcryoSPARCv4.7.0
MODEL REFINEMENTPHENIX1.21.2_5419
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY11455833