☰ Navigation Tabs
NMR Structure of the C-terminal Coiled-Coil Domain of CIN85
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 2D 1H-15N TROSY-HSQC 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 2 2D 1H-13C HSQC aliphatic 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 3 3D HNCACB 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 4 3D HNCO 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 5 3D HN(CA)CO 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 6 3D 1H-15N NOESY 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305 7 3D 1H-13C NOESY aliphatic 1-3 mM [U-13C; U-15N; U-2H] CIN85 CC-domain, 1-3 mM [U-2H] CIN85 CC-domain 95% H2O/5% D2O 6.9 ambient 305
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE 800
NMR Refinement Method Details Software torsion angle dynamics posterior sampling using Markov chain Monte Carlo (replica exchange simulation) CARA
NMR Ensemble Information Conformer Selection Criteria every 84th structure after convergence Conformers Calculated Total Number 2440 Conformers Submitted Total Number 30 Representative Model 1 (closest to the average)
Computation: NMR Software # Classification Version Software Name Author 1 chemical shift assignment CARA 1.8.4 Keller and Wuthrich 2 peak picking CARA 1.8.4 Keller and Wuthrich 3 refinement ISD_(Inferential_structure_determination) Rieping, Habeck, and Nilges