2JWP
Malectin
SOLUTION NMR
NMR Experiment | ||||||||
---|---|---|---|---|---|---|---|---|
Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
1 | 3D HNCA | 0.5 mM [U-99% 13C; U-99% 15N] malectin | 90% H2O/10% D2O | 150 | 6.8 | ambient | 295 | |
2 | 3D HNCACB | 0.5 mM [U-99% 13C; U-99% 15N] malectin | 90% H2O/10% D2O | 150 | 6.8 | ambient | 295 | |
3 | 3D CBCA(CO)NH | 0.5 mM [U-99% 13C; U-99% 15N] malectin | 90% H2O/10% D2O | 150 | 6.8 | ambient | 295 | |
4 | 3D 1H-15N NOESY | 0.5 mM [U-99% 13C; U-99% 15N] malectin | 90% H2O/10% D2O | 150 | 6.8 | ambient | 295 | |
5 | 3D 1H-13C NOESY | 0.5 mM [U-99% 13C; U-99% 15N] malectin | 90% H2O/10% D2O | 150 | 6.8 | ambient | 295 |
NMR Spectrometer Information | |||
---|---|---|---|
Spectrometer | Manufacturer | Model | Field Strength |
1 | Bruker | DRX | 600 |
2 | Bruker | DRX | 500 |
3 | Bruker | DRX | 900 |
NMR Refinement | ||
---|---|---|
Method | Details | Software |
simulated annealing | ARIA |
NMR Ensemble Information | |
---|---|
Conformer Selection Criteria | structures with the lowest energy |
Conformers Calculated Total Number | 200 |
Conformers Submitted Total Number | 10 |
Representative Model | 1 (fewest violations) |
Computation: NMR Software | ||||
---|---|---|---|---|
# | Classification | Version | Software Name | Author |
1 | data analysis | ARIA | Linge, O'Donoghue and Nilges | |
2 | data analysis | CNS | Brunger, Adams, Clore, Gros, Nilges and Read |