Skip to main content

 29BY | pdb_000029by

Cryo-EM structure of human DHX9 in complex with ATX-968 and ADP.


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelOther 

Data Collection

Overall
ID #Resolution (High)Resolution (Low)Percent Possible (Observed)R Merge I (Observed)Rrim I (All)Rpim I (All)CC (Half)Net I Over Average Sigma (I)RedundancyNumber Reflections (All)Number Reflections (Observed)Observed Criterion Sigma (F)Observed Criterion Sigma (I)B (Isotropic) From Wilson Plot
13.449.731000.1510.1570.0420.99811.813.681625
Highest Resolution Shell
ID #Resolution (High)Resolution (Low)Percent Possible (All)Percent Possible (Observed)R Merge I (Observed)Rrim I (All)Rpim I (All)CC (Half)Mean I Over Sigma (Observed)RedundancyNumber Unique Reflections (All)
13.43.461003.6123.7470.9940.514
Sample
Human DHX9 bound to ATX-968 and ADP.
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsSample was centrifuged at 21,000 x g for 10 minutes at 6 degrees Celsius and diluted to 0.5 mg/mL (4.34 micromolar) just before grid preparation. 3 mi ...Sample was centrifuged at 21,000 x g for 10 minutes at 6 degrees Celsius and diluted to 0.5 mg/mL (4.34 micromolar) just before grid preparation. 3 microlitres of the sample was applied to the grid, blotted for 3 seconds with a blot force of 3, and immediately flash frozen.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles985972
Reported Resolution (Å)2.8
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Target
Overall B Value64.98
Fitting Procedure
DetailsInitial fit was done in Chimera, followed by chain adjustments in Coot and refinement in Phenix.
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)60
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)400
Maximum Defocus (nm)1800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsPreliminary grid screening was performed in a Glacios.
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.7.0
IMAGE ACQUISITIONEPU3.4
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot
MODEL REFINEMENTPHENIX
INITIAL EULER ASSIGNMENTRELION5.0
FINAL EULER ASSIGNMENTRELION5.0
CLASSIFICATIONRELION5.0
RECONSTRUCTIONRELION5.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION