28UK | pdb_000028uk

E. coli 70S ribosome, conformational ground state mutation in SSU-h41, with A- and P-site tRNA


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 7K00 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.033
r_dihedral_angle_6_deg10.007
r_dihedral_angle_1_deg5.479
r_lrange_it4.681
r_lrange_other4.681
r_dihedral_angle_2_deg3.228
r_mcangle_it3.002
r_mcangle_other3.002
r_scangle_it2.471
r_scangle_other2.471
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_3_deg10.033
r_dihedral_angle_6_deg10.007
r_dihedral_angle_1_deg5.479
r_lrange_it4.681
r_lrange_other4.681
r_dihedral_angle_2_deg3.228
r_mcangle_it3.002
r_mcangle_other3.002
r_scangle_it2.471
r_scangle_other2.471
r_mcbond_it1.653
r_mcbond_other1.653
r_scbond_it1.397
r_scbond_other1.397
r_angle_refined_deg0.744
r_dihedral_angle_other_2_deg0.475
r_angle_other_deg0.278
r_nbtor_refined0.221
r_symmetry_nbd_other0.179
r_nbd_refined0.142
r_xyhbond_nbd_refined0.115
r_symmetry_nbtor_other0.073
r_metal_ion_refined0.069
r_chiral_restr0.029
r_symmetry_xyhbond_nbd_other0.021
r_bond_refined_d0.004
r_gen_planes_refined0.003
r_gen_planes_other0.001
r_bond_other_d
Sample
E. coli 70S ribosome
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles23232
Reported Resolution (Å)2.24
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7K00)
Refinement SpaceRECIPROCAL
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)49.88
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)300
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.5.1
IMAGE ACQUISITIONEPU
CTF CORRECTIONcryoSPARC4.5.1
MODEL FITTINGUCSF ChimeraX1.8
MODEL REFINEMENTREFMAC5.8.0430
INITIAL EULER ASSIGNMENTcryoSPARC4.5.1
FINAL EULER ASSIGNMENTcryoSPARC4.6.2
CLASSIFICATIONcryoSPARC4.5.1
RECONSTRUCTIONcryoSPARC4.6.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION