20ZC | pdb_000020zc

Cryo-EM structure of human Neurotensin Receptor 1 (hNTSR1)-Gi1 (delipidated) complex in nucleotide-free C state


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined27.918
r_long_range_B_other27.917
r_scangle_other17.513
r_dihedral_angle_3_deg16.43
r_mcangle_it13.078
r_mcangle_other13.077
r_scbond_other10.663
r_scbond_it10.662
r_mcbond_it8.284
r_mcbond_other8.283
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined27.918
r_long_range_B_other27.917
r_scangle_other17.513
r_dihedral_angle_3_deg16.43
r_mcangle_it13.078
r_mcangle_other13.077
r_scbond_other10.663
r_scbond_it10.662
r_mcbond_it8.284
r_mcbond_other8.283
r_dihedral_angle_1_deg6.307
r_dihedral_angle_2_deg3.566
r_angle_refined_deg2.132
r_angle_other_deg0.847
r_chiral_restr0.109
r_bond_refined_d0.009
r_gen_planes_refined0.009
r_gen_planes_other0.003
r_bond_other_d
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
JMV449-bound human Neurotensin Receptor 1 (hNTSR1)-Gi1 (delipidated) complex in nucleotide-free C state with scFv16
Sample Components
JMV449-bound human neurotensin receptor type 1
heterotrimeric Gi1 protein (delipidated)
scFv16
Specimen Preparation
Sample Aggregation StatePARTICLE
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles520529
Reported Resolution (Å)2.6
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)1600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC
RECONSTRUCTIONcryoSPARC
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
NONE