1D4B
CIDE-N DOMAIN OF HUMAN CIDE-B
SOLUTION NMR
NMR Experiment | ||||||||
---|---|---|---|---|---|---|---|---|
Experiment | Type | Sample Contents | Solvent | Ionic Strength | pH | Pressure | Temperature (K) | Spectrometer |
1 | A MINIMAL SET OF NMR EXPERIMENTS REQUIRED FOR HIGH-RESOLUTION STRUCTURE DETERMINATION | 0.5MM CIDE-N OF CIDE-B | 0.15 | 6.6 | 1 atm | 298 |
NMR Spectrometer Information | |||
---|---|---|---|
Spectrometer | Manufacturer | Model | Field Strength |
1 | Bruker | DRX | 600 |
2 | Bruker | DRX | 500 |
3 | Varian | UNITY | 500 |
4 | Varian | INOVA | 750 |
NMR Refinement | ||
---|---|---|
Method | Details | Software |
DISTANCE GEOMETRY SIMULATED ANNEALING TORSION ANGLE DYNAMICS RELAXATION DATA | X-PLOR |
NMR Ensemble Information | |
---|---|
Conformer Selection Criteria | STRUCTURES WITH THE LEAST RESTRAINT VIOLATIONS,STRUCTURES WITH THE LOWEST ENERGY |
Conformers Calculated Total Number | 30 |
Conformers Submitted Total Number | 15 |
Representative Model | 1 (fewest violations,lowest energy) |
Additional NMR Experimental Information | |
---|---|
Details | THE STRUCTURE WAS DETERMINED USING MULTIDIMENTIONAL NMR SPECTROSCOPY |
Computation: NMR Software | ||||
---|---|---|---|---|
# | Classification | Version | Software Name | Author |
1 | refinement | X-PLOR | 3.18 | BRUNGER |
2 | structure solution | DYANA | 1.5 | GUNTERT |