9Z77 | pdb_00009z77

Cryo-EM structure of Enterotoxigenic Escherichia coli autotransporter A (EatA) complexed with the fragment antigen binding domain of monoclonal antibody G12


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFold 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d4.6993
f_angle_d0.6956
f_chiral_restr0.0509
f_plane_restr0.0065
f_bond_d0.0032
Sample
Binary complex of the recombinant EatA passenger domain with Fab G12
Sample Components
Enterotoxigenic Escherichia coli autotransporter A (EatA) passenger domain
Fragment antigen binding domain of monoclonal antibody G12
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification DetailsAdded 1X Lauryl Maltose Neopentyl Glycol (LMNG) detergent to sample prior to vitrification.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles73337
Reported Resolution (Å)3.7
Resolution MethodOTHER
Other DetailsEstimated resolution of composite map.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetCross-correlation coefficient
Overall B Value
Fitting Procedure
DetailsRigid body fitting of AlphaFold-derived models was done in ChimeraX, followed by multiple rounds of local fitting in Coot and Phenix real-space refine ...Rigid body fitting of AlphaFold-derived models was done in ChimeraX, followed by multiple rounds of local fitting in Coot and Phenix real-space refinement
Data Acquisition
Detector TypeGATAN K3 BIOCONTINUUM (6k x 4k)
Electron Dose (electrons/Å**2)49
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2400
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification105000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.7.1
IMAGE ACQUISITIONSerialEM4
CTF CORRECTIONcryoSPARC4.7.1
MODEL FITTINGUCSF ChimeraX1.8
MODEL FITTINGCoot0.9.8.7
INITIAL EULER ASSIGNMENTcryoSPARC4.7.1
FINAL EULER ASSIGNMENTcryoSPARC4.7.1
RECONSTRUCTIONcryoSPARC4.7.1
MODEL REFINEMENTPHENIX1.21_5207
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1244157Initial particle set was obtained by CryoSegNet AI picking, followed by cryoSPARC 2D classification to redo particle picking with 2D templates