9S7P | pdb_00009s7p

Cryo-EM structure of amyloidogenic antimicrobial peptide Brevinin-1OKc polymorph 1 in PBS pH 6.5


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
otherOther 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined15.492
r_long_range_B_other15.492
r_mcangle_it8.888
r_mcangle_other8.883
r_scangle_other6.58
r_dihedral_angle_1_deg6.111
r_dihedral_angle_3_deg5.746
r_mcbond_it5.071
r_mcbond_other5.071
r_scbond_it3.62
RMS Deviations
KeyRefinement Restraint Deviation
r_long_range_B_refined15.492
r_long_range_B_other15.492
r_mcangle_it8.888
r_mcangle_other8.883
r_scangle_other6.58
r_dihedral_angle_1_deg6.111
r_dihedral_angle_3_deg5.746
r_mcbond_it5.071
r_mcbond_other5.071
r_scbond_it3.62
r_scbond_other3.617
r_angle_refined_deg1.242
r_angle_other_deg0.471
r_chiral_restr0.052
r_gen_planes_refined0.008
r_bond_refined_d0.007
r_gen_planes_other0.001
r_bond_other_d
r_dihedral_angle_2_deg
r_dihedral_angle_4_deg
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Brevinin-1OKc
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles498395
Reported Resolution (Å)2.17
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC2
Axial Rise1.6
Angular Rotation59.49
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.9.8.92
MODEL REFINEMENTServalcat
INITIAL EULER ASSIGNMENTRELION5
FINAL EULER ASSIGNMENTRELION5
CLASSIFICATIONRELION5
RECONSTRUCTIONRELION5
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1523940