☰ Navigation Tabs
Cryo-EM structure of SKM-70S ribosomal stalled complex in the A-tRNA positioned (Body open) state.
Refinement RMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 19.031 r_long_range_B_other 18.978 r_scangle_other 15.773 r_mcangle_it 14.684 r_mcangle_other 14.684 r_dihedral_angle_3_deg 13.724 r_scbond_it 10.542 r_scbond_other 10.512 r_mcbond_it 10.265 r_mcbond_other 10.265
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_long_range_B_refined 19.031 r_long_range_B_other 18.978 r_scangle_other 15.773 r_mcangle_it 14.684 r_mcangle_other 14.684 r_dihedral_angle_3_deg 13.724 r_scbond_it 10.542 r_scbond_other 10.512 r_mcbond_it 10.265 r_mcbond_other 10.265 r_dihedral_angle_1_deg 7.803 r_dihedral_angle_2_deg 2.55 r_angle_refined_deg 1.135 r_angle_other_deg 0.435 r_chiral_restr 0.05 r_gen_planes_refined 0.012 r_bond_refined_d 0.008 r_gen_planes_other 0.003 r_bond_other_d 0.001 r_dihedral_angle_4_deg r_nbd_refined r_nbd_other r_nbtor_refined r_nbtor_other r_xyhbond_nbd_refined r_xyhbond_nbd_other r_metal_ion_refined r_metal_ion_other r_symmetry_vdw_refined r_symmetry_vdw_other r_symmetry_hbond_refined r_symmetry_hbond_other r_symmetry_metal_ion_refined r_symmetry_metal_ion_other r_scangle_it r_rigid_bond_restr r_sphericity_free r_sphericity_bonded
Hide All Keys
Sample Cryo-EM structure of SKM-70S ribosomal stalled complex in the A-tRNA positioned (Body open) state.
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument Cryogen Name ETHANE-PROPANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 103241 Reported Resolution (Å) 2.62 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 1.14
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 500 Maximum Defocus (nm) 5000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION crYOLO 1.9.7 MODEL REFINEMENT REFMAC 5.8.0425 RECONSTRUCTION RELION 5
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION