☰ Navigation Tabs
Cryo-EM structure of the type I pilus from enterotoxigenic Escherichia coli
Sample Type-1 fimbrial protein FimA
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 43184 Reported Resolution (Å) 2.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 7.71 Angular Rotation 114.95
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol AB INITIO MODEL Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 53.77
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model JEOL CRYO ARM 300 Minimum Defocus (nm) 1400 Maximum Defocus (nm) 1600 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION