9EME

AL amyloid fibril from the FOR103 light chain


ELECTRON MICROSCOPY
Sample
lambda 3 immunoglobulin light chain fragment
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification InstrumentLEICA PLUNGER
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodHELICAL
Number of Particles120039
Reported Resolution (Å)2.92
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypeHELICAL
Axial SymmetryC1
Axial Rise4.752
Angular Rotation1.309
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolBACKBONE TRACE
Refinement Targetcorrelation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)53.7
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.1.3
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGCoot0.9.2
MODEL REFINEMENTPHENIX
RECONSTRUCTIONRELION5.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION157862