9EMC

RUVBL1/2 in complex with ATP


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelOther 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d8.54
f_angle_d1.409
f_chiral_restr0.082
f_bond_d0.011
f_plane_restr0.01
Sample
Hetero-hexameric RUVBL1-RUVBL2 complex bound to ATP and the CB-6644 inhibitor
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles29748
Reported Resolution (Å)3.26
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC3
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolBACKBONE TRACE
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOCONTINUUM (6k x 4k)
Electron Dose (electrons/Å**2)45
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)500
Maximum Defocus (nm)2800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONTopaz0.2
PARTICLE SELECTIONRELION4.0
IMAGE ACQUISITIONEPU3.4.0
CTF CORRECTIONCTFFIND4.1
MODEL FITTINGUCSF ChimeraX
MODEL REFINEMENTISOLDE1.7
MODEL REFINEMENTPHENIX1.20.1-4487
MODEL REFINEMENTCoot0.9.8.5
INITIAL EULER ASSIGNMENTRELION4.0
FINAL EULER ASSIGNMENTRELION4.0
CLASSIFICATIONRELION4.0
RECONSTRUCTIONRELION4.0
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION