☰ Navigation Tabs
Structure of URAT1 in complex with benzbromarone
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 8ET6
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 7.402 f_angle_d 0.556 f_chiral_restr 0.036 f_plane_restr 0.007 f_bond_d 0.002
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument LEICA EM GP Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 220530 Reported Resolution (Å) 3 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT
Map-Model Fitting and Refinement Id 1 (8ET6) Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value 200 Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 50
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2000 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification 105000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION Topaz 0.24 IMAGE ACQUISITION Latitude 3.5 CTF CORRECTION cryoSPARC 4.0 MODEL FITTING Coot 0.96 MODEL REFINEMENT PHENIX 1.21 INITIAL EULER ASSIGNMENT cryoSPARC 4.0 FINAL EULER ASSIGNMENT cryoSPARC 4.0 CLASSIFICATION cryoSPARC RECONSTRUCTION cryoSPARC 4.0
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 7735079