8Z3S

Activation mechanism and novel binding site of the BKCa channel activator CTIBD


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6V38 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d15.669
f_angle_d0.685
f_chiral_restr0.046
f_bond_d0.005
f_plane_restr0.004
Sample
Calcium-activated potassium channel subunit alpha-1 (Slo1)
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles288878
Reported Resolution (Å)3.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1 (6V38)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1400
Maximum Defocus (nm)2600
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification73000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.3.2
PARTICLE SELECTIONcryoSPARC3.3.2
CTF CORRECTIONcryoSPARC3.3.2
MODEL FITTINGUCSF Chimera
MODEL FITTINGPHENIX
CLASSIFICATIONcryoSPARC3.3.2
RECONSTRUCTIONcryoSPARC3.3.2
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION700885