8UZ1
Straight actin filament from Arp2/3 branch junction sample (ADP-BeFx)
ELECTRON MICROSCOPY
Sample |
---|
Arp2/3 branch complex (ADP-BeFx state) |
Sample Components |
Arp2/3 complex |
Actin |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | The samples were incubated on the grid for 50 s and the extra solution was blotted using two Vitrobot filter papers (0.55/20 mm, Grade 595, Ted Pella) ... |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 543085 |
Reported Resolution (Å) | 3.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | For the final 3D reconstruction, no helical symmetry was applied |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 27.38 |
Angular Rotation | -166.74 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | |||||
Refinement Protocol | |||||
Refinement Target | |||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K3 (6k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 51.4 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1200 |
Maximum Defocus (nm) | 2500 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 64000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details | The vitrified grids were screened for sample homogeneity and ice thickness in a Glacios 200 kV transmission electron microscope equipped with Gatan K2 summit camera. Electron micrographs for image reconstructions were collected using Titan Krios equipped with X-cold field emission gun at 300 kV, Gatan image filter with slit width of 20 eV and a nanoprobe. |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
FINAL EULER ASSIGNMENT | cryoSPARC | 3.0 |
CLASSIFICATION | cryoSPARC | 3.0 |
RECONSTRUCTION | cryoSPARC | 3.0 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 1611831 |