8PS2

Asymmetric unit of the yeast fatty acid synthase with ACP at the enoyl reductase domain (FASam sample)


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.183
r_dihedral_angle_4_deg14.988
r_dihedral_angle_3_deg14.262
r_long_range_B_refined12.636
r_long_range_B_other12.635
r_scangle_other9.815
r_mcangle_other7.412
r_mcangle_it7.411
r_dihedral_angle_1_deg6.18
r_scbond_it5.89
RMS Deviations
KeyRefinement Restraint Deviation
r_dihedral_angle_2_deg35.183
r_dihedral_angle_4_deg14.988
r_dihedral_angle_3_deg14.262
r_long_range_B_refined12.636
r_long_range_B_other12.635
r_scangle_other9.815
r_mcangle_other7.412
r_mcangle_it7.411
r_dihedral_angle_1_deg6.18
r_scbond_it5.89
r_scbond_other5.89
r_mcbond_it4.728
r_mcbond_other4.72
r_angle_refined_deg1.464
r_angle_other_deg1.21
r_chiral_restr0.063
r_bond_refined_d0.007
r_gen_planes_refined0.006
r_bond_other_d0.002
r_gen_planes_other0.002
r_nbd_refined
r_nbd_other
r_nbtor_refined
r_nbtor_other
r_xyhbond_nbd_refined
r_xyhbond_nbd_other
r_metal_ion_refined
r_metal_ion_other
r_symmetry_vdw_refined
r_symmetry_vdw_other
r_symmetry_hbond_refined
r_symmetry_hbond_other
r_symmetry_metal_ion_refined
r_symmetry_metal_ion_other
r_scangle_it
r_rigid_bond_restr
r_sphericity_free
r_sphericity_bonded
Sample
Yeast fatty acid synthase
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles249482
Reported Resolution (Å)2.9
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)5000
Maximum Defocus (nm)25000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND4.1.14
INITIAL EULER ASSIGNMENTRELION3.1
FINAL EULER ASSIGNMENTRELION3.1
RECONSTRUCTIONRELION3.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION