☰ Navigation Tabs
Alzheimer's disease paired-helical filament in complex with PET tracer GTP-1
Sample Alzheimer's tau paired helical filament in complex with PET ligand GTP-1
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 30199 Reported Resolution (Å) 2.7 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 2.37 Angular Rotation 179.45
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 46
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) 800 Maximum Defocus (nm) 1800 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS 2.7 Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 3.1 IMAGE ACQUISITION SerialEM CTF CORRECTION CTFFIND 4.1 MODEL FITTING PHENIX MODEL REFINEMENT PHENIX CLASSIFICATION RELION 3.1 RECONSTRUCTION RELION 3.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION 380428