☰ Navigation Tabs
Cryo-EM structure of BCL10 R58Q filament
Refinement RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 9.467 f_angle_d 0.789 f_chiral_restr 0.052 f_bond_d 0.005 f_plane_restr 0.004
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK III Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 30000 Reported Resolution (Å) 4.6 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 5 Angular Rotation -100.8
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 38
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TALOS ARCTICA Minimum Defocus (nm) 1000 Maximum Defocus (nm) 2500 Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification 36000 Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
EM Software Task Software Package Version RECONSTRUCTION RELION 3.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details NONE