8BHT

ABCG2 turnover-1 state with tariquidar bound


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d13.4416
f_angle_d0.6531
f_chiral_restr0.0399
f_bond_d0.0072
f_plane_restr0.003
Sample
ABCG2 in complex with Tariquidar under turnover condition
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles211906
Reported Resolution (Å)3.1
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolOTHER
Refinement Targetcross-correlation coefficient
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)600
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC2.15
IMAGE ACQUISITIONEPU2
CTF CORRECTIONGctf
MODEL FITTINGCoot0.9.2
INITIAL EULER ASSIGNMENTcryoSPARC2.15
FINAL EULER ASSIGNMENTcryoSPARC2.15
CLASSIFICATIONcryoSPARC2.15
RECONSTRUCTIONcryoSPARC2.15
MODEL REFINEMENTPHENIX1.18.2
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2939835