7SJ8
13pf wildtype microtubule from recombinant human tubulin decorated with kinesin
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 6DPU |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 14.311 |
f_angle_d | 0.563 |
f_chiral_restr | 0.042 |
f_bond_d | 0.005 |
f_plane_restr | 0.004 |
Sample |
---|
13pf wildtype microtubule from recombinant human tubulin and decorated with kinesin |
Specimen Preparation | |
---|---|
Sample Aggregation State | HELICAL ARRAY |
Vitrification Instrument | |
Cryogen Name | ETHANE-PROPANE |
Sample Vitrification Details | 30 second adsorption time onto grid. blot force 15, 4 second blot time, 37 degrees, and 100 percent humidity. 0.5 second drain time. |
3D Reconstruction | |
---|---|
Reconstruction Method | HELICAL |
Number of Particles | 23364 |
Reported Resolution (Å) | 3.6 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | HELICAL |
Axial Symmetry | C1 |
Axial Rise | 81.69 |
Angular Rotation | -0.09 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (6DPU) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | RIGID BODY FIT | ||||
Refinement Target | Correlation Coefficient | ||||
Overall B Value | 115 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 40 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 700 |
Maximum Defocus (nm) | 2400 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.6 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 64000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | SerialEM | |
CTF CORRECTION | CTFFIND | 4 |
CTF CORRECTION | RELION | 3.1 |
MODEL FITTING | PHENIX | dev-2883 |
MODEL REFINEMENT | PHENIX | dev-2883 |
INITIAL EULER ASSIGNMENT | RELION | 3.1 |
FINAL EULER ASSIGNMENT | FREALIGN | 9.11 |
CLASSIFICATION | RELION | 3.1 |
RECONSTRUCTION | FREALIGN | 9.11 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | CTFFind4 and CTFRefine were used within the RELION3.1 framework. | Microtubules were picked within RELION 3.1 helical picking functionality and extracted along the filament with an 82A sliding box. |