Cryo-EM structure of TMEM106B fibrils extracted from a FTLD-TDP patient, polymorph 2
Sample TMEM106B fibrils, polymorph 2
Specimen Preparation Sample Aggregation State FILAMENT Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 16883 Reported Resolution (Å) 3.2 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C2 Axial Rise 4.91 Angular Rotation 179.59
Map-Model Fitting and Refinement Id 1 Refinement Space REAL Refinement Protocol FLEXIBLE FIT Refinement Target Overall B Value 93 Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 (6k x 4k) Electron Dose (electrons/Å**2) 39
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION crYOLO IMAGE ACQUISITION Leginon CTF CORRECTION CTFFIND 4.1.8 INITIAL EULER ASSIGNMENT RELION 2 FINAL EULER ASSIGNMENT RELION 2 RECONSTRUCTION RELION 3 MODEL REFINEMENT PHENIX real_space_refine
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION