Find PDB structures and Computed Structure Models (CSM) by combining queries from tools in this suite: Attribute Search, Sequence Similarity, Sequence Motif, 3D Similarity, and 3D Motif with 'AND' logic.
Spike protein (S-6P) in complex with Synthetic nanobody (Sb45)
Specimen Preparation
Sample Aggregation State
PARTICLE
Vitrification Instrument
FEI VITROBOT MARK IV
Cryogen Name
ETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction Method
SINGLE PARTICLE
Number of Particles
214171
Reported Resolution (Å)
3.02
Resolution Method
FSC 0.143 CUT-OFF
Other Details
A series of "Ab-initio 3D reconstruction" dividing 2 or 4 subclasses to identify two forms of configurations of S-6P, i.e. one RBD up or two RBD up.
Refinement Type
Symmetry Type
POINT
Point Symmetry
C1
Map-Model Fitting and Refinement
Id
1 (6XKL, 6XKL, 6XKL, 7KGJ, 7KGJ, 7B32)
Refinement Space
REAL
Refinement Protocol
RIGID BODY FIT
Refinement Target
Correlation Coefficient
Overall B Value
157
Fitting Procedure
Details
An initial model for S-6P was generated using PDB 6XKL and rigid body fitted into the map using Chimera. The RBD domain (334-528) and Sb45 are taken f ...
An initial model for S-6P was generated using PDB 6XKL and rigid body fitted into the map using Chimera. The RBD domain (334-528) and Sb45 are taken from 7KGJ which was superimposed onto the S-6P model in PyMol. The NTD domain (14-289) is taken from 7B32 with full sequence and replace that of 6XKL. We have rebuilt and added more glycans (NAGs). We used the real-space refinement in PHENIX including rigid-body refinement. RBD and NTD are subjected to rigid-body refinement. Simulate annealing (SA) runs once at the initial micro-step, local grid search and ADP refinements were included, using the secondary structure restraints.
Data Acquisition
Detector Type
GATAN K2 QUANTUM (4k x 4k)
Electron Dose (electrons/Å**2)
56
Imaging Experiment
1
Date of Experiment
Temperature (Kelvin)
Microscope Model
FEI TITAN KRIOS
Minimum Defocus (nm)
700
Maximum Defocus (nm)
2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
2.7
Imaging Mode
BRIGHT FIELD
Specimen Holder Model
FEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
130000
Calibrated Magnification
47529
Source
FIELD EMISSION GUN
Acceleration Voltage (kV)
300
Imaging Details
EM Software
Task
Software Package
Version
PARTICLE SELECTION
cryoSPARC
v3.2.0
IMAGE ACQUISITION
SerialEM
3.8.0
CTF CORRECTION
cryoSPARC
v3.2.0
MODEL FITTING
UCSF Chimera
2021
MODEL REFINEMENT
PHENIX
1.19.2
CLASSIFICATION
cryoSPARC
3.2.0
RECONSTRUCTION
cryoSPARC
V3.2.0
Image Processing
CTF Correction Type
CTF Correction Details
Number of Particles Selected
Particle Selection Details
NONE
patch CTF estimation
1433963
A total of 9,725 micrographs were imported into cryoSPARC. Following patch Motion correction, patch CTF estimation, and curation, the number of micrographs was reduced to 9,237. The blob picker with the particle diameter between 128 and 256 angstroms was used for picking up particles. We used the box size of 400 pixels and extracted 1,433,963 particles initially.