7KZX
Cryo-EM structure of YiiP-Fab complex in Apo state
ELECTRON MICROSCOPY
Starting Model(s)
Initial Refinement Model(s) | |||
---|---|---|---|
Type | Source | Accession Code | Details |
experimental model | PDB | 5VRF |
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
f_dihedral_angle_d | 6.6961 |
f_angle_d | 0.7537 |
f_chiral_restr | 0.0451 |
f_bond_d | 0.006 |
f_plane_restr | 0.0056 |
Sample |
---|
YiiP_SO in complex with Fab2R |
Sample Components |
YiiP |
Fab2R_light chain |
Fab2R_heavy chain |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | 3ul of protein mixture applied to grid. Blot time 4 seconds, blot force 0. |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 140565 |
Reported Resolution (Å) | 4 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (5VRF) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | BACKBONE TRACE | ||||
Refinement Target | cross-correlation | ||||
Overall B Value | 101 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 QUANTUM (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 65 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | 1500 |
Maximum Defocus (nm) | 3000 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | 130000 |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | 2.90 |
CTF CORRECTION | cryoSPARC | 2.9.0 |
MODEL FITTING | UCSF Chimera | 1.13.1 |
INITIAL EULER ASSIGNMENT | cryoSPARC | 2.9.0 |
FINAL EULER ASSIGNMENT | cryoSPARC | 2.9.0 |
CLASSIFICATION | cryoSPARC | 2.9.0 |
RECONSTRUCTION | cryoSPARC | 2.9.0 |
MODEL REFINEMENT | PHENIX | 1.18 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | 848576 |