☰ Navigation Tabs
Cryo-EM structure of VCCN1 in lipid nanodisc
Refinement RMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 27.394 r_dihedral_angle_4_deg 19.259 r_lrange_it 18.398 r_lrange_other 18.379 r_dihedral_angle_3_deg 15.073 r_scangle_it 14.287 r_scangle_other 14.287 r_mcangle_other 9.867 r_mcangle_it 9.863 r_scbond_it 9.587
Show All KeysRMS Deviations Key Refinement Restraint Deviation r_dihedral_angle_2_deg 27.394 r_dihedral_angle_4_deg 19.259 r_lrange_it 18.398 r_lrange_other 18.379 r_dihedral_angle_3_deg 15.073 r_scangle_it 14.287 r_scangle_other 14.287 r_mcangle_other 9.867 r_mcangle_it 9.863 r_scbond_it 9.587 r_scbond_other 9.584 r_mcbond_it 7.468 r_mcbond_other 7.453 r_dihedral_angle_1_deg 4.734 r_angle_refined_deg 1.728 r_angle_other_deg 1.704 r_ext_dist_refined_d 0.314 r_xyhbond_nbd_refined 0.225 r_nbd_refined 0.193 r_symmetry_xyhbond_nbd_refined 0.187 r_nbd_other 0.17 r_nbtor_refined 0.163 r_symmetry_nbd_other 0.153 r_symmetry_nbd_refined 0.102 r_symmetry_nbtor_other 0.074 r_chiral_restr 0.055 r_bond_other_d 0.05 r_bond_refined_d 0.013 r_gen_planes_refined 0.004 r_gen_planes_other 0.001
Hide All Keys
Sample Bestrophin-like protein
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 345938 Reported Resolution (Å) 2.7 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C5
Map-Model Fitting and Refinement Id 1 Refinement Space Refinement Protocol Refinement Target Overall B Value Fitting Procedure Details
Data Acquisition Detector Type GATAN K3 BIOQUANTUM (6k x 4k) Electron Dose (electrons/Å**2) 48
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model TFS KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version PARTICLE SELECTION RELION 3.1 CTF CORRECTION CTFFIND 4.1.13 INITIAL EULER ASSIGNMENT RELION 3.1 FINAL EULER ASSIGNMENT RELION 3.1 RECONSTRUCTION RELION 3.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION