SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
12D 1H-1H NOESY1 mM 1H cyclic hexa peptide93% H2O/7% D2Onone51 atm298Bruker AVANCE 600
22D 1H-1H TOCSY1 mM 1H cyclic hexa peptide93% H2O/7% D2Onone51 atm298Bruker AVANCE 600
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE600
NMR Refinement
MethodDetailsSoftware
simulated annealingX-PLOR NIH
NMR Ensemble Information
Conformer Selection Criteriastructures with the lowest energy
Conformers Calculated Total Number50
Conformers Submitted Total Number10
Representative Model1 (lowest energy)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1refinementX-PLOR NIHSchwieters, Kuszewski, Tjandra and Clore
3chemical shift assignmentTopSpinBruker Biospin
4peak pickingTopSpinBruker Biospin