6O8Y
Cryo-EM image reconstruction of the 70S Ribosome Enterococcus faecalis Class03
ELECTRON MICROSCOPY
Sample |
---|
Enterococcus faecalis |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | FEI VITROBOT MARK IV |
Cryogen Name | ETHANE |
Sample Vitrification Details | Vol = 4 uL, BT = 4 sec, BF = 0, DT = 0, WT = 8 sec |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 18979 |
Reported Resolution (Å) | 4.14 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 (5LI0, 4YBB) | ||||
Refinement Space | REAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | Correlation Coefficient | ||||
Overall B Value | 177 | ||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 QUANTUM (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 25 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | FEI TITAN KRIOS |
Minimum Defocus (nm) | |
Maximum Defocus (nm) | |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
IMAGE ACQUISITION | Leginon | |
CTF CORRECTION | CTFFIND | 4.0 |
MODEL FITTING | Coot | 0.8.9.1 |
MODEL REFINEMENT | PHENIX | 1.14_3235 |
INITIAL EULER ASSIGNMENT | RELION | 2 |
FINAL EULER ASSIGNMENT | cryoSPARC | 0.63 |
CLASSIFICATION | FREALIGN | 9.03 |
RECONSTRUCTION | cryoSPARC | 0.63 |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION |