6NR2

Cryo-EM structure of the TRPM8 ion channel in complex with the menthol analog WS-12 and PI(4,5)P2


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6BPQ 
Sample
Transient receptor potential melastatin member 8
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles46940
Reported Resolution (Å)4
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC4
Map-Model Fitting and Refinement
Id1 (6BPQ)
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value100
Fitting Procedure
Details
Data Acquisition
Detector TypeFEI FALCON III (4k x 4k)
Electron Dose (electrons/Å**2)42
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1250
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification75000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU
CTF CORRECTIONRELION3.0
CTF CORRECTIONGctf1.18
MODEL FITTINGCoot0.8.8
INITIAL EULER ASSIGNMENTRELION3.0
FINAL EULER ASSIGNMENTRELION3.0
RECONSTRUCTIONRELION3.0
MODEL REFINEMENTPHENIX1.12-2829
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1622434