☰ Navigation Tabs
BEST1 open state W287F mutant, calcium-free
Starting Model(s) Initial Refinement Model(s) Type Source Accession Code Details experimental model PDB 4RDQ
Sample BEST1 open state W287F mutant, calcium-free
Specimen Preparation Sample Aggregation State PARTICLE Vitrification Instrument FEI VITROBOT MARK IV Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method SINGLE PARTICLE Number of Particles 153359 Reported Resolution (Å) 3 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type POINT Point Symmetry C5
Map-Model Fitting and Refinement Id 1 (4RDQ) Refinement Space REAL Refinement Protocol OTHER Refinement Target Overall B Value 87 Fitting Procedure Details
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 76
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TITAN KRIOS Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model FEI TITAN KRIOS AUTOGRID HOLDER Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 300 Imaging Details
EM Software Task Software Package Version CTF CORRECTION CTFFIND 4.1.9 MODEL FITTING Coot 0.8.9.1 MODEL REFINEMENT PHENIX 1.13 INITIAL EULER ASSIGNMENT RELION 2.1 CLASSIFICATION RELION 2.1
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION