☰ Navigation Tabs
NMR solution structure of Roseltide rT7
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 2D 1H-1H NOESY 1.0 mM Roseltide 90% H2O/10% D2O 0 mM 4 1 atm 307 Bruker AVANCE 800 2 2D 1H-1H TOCSY 1.0 mM Roseltide 90% H2O/10% D2O 0 mM 4 1 atm 307 Bruker AVANCE 800 3 2D 1H-1H ROESY 1.0 mM Roseltide 90% H2O/10% D2O 0 mM 4 1 atm 307 Bruker AVANCE 800
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE 800
NMR Refinement Method Details Software simulated annealing CNS
NMR Ensemble Information Conformer Selection Criteria structures with the lowest energy Conformers Calculated Total Number 100 Conformers Submitted Total Number 17 Representative Model 1 (lowest energy)
Computation: NMR Software # Classification Version Software Name Author 1 refinement CNS Brunger A. T. et.al. 2 data analysis Sparky Goddard 3 processing NMRPipe Delaglio, Grzesiek, Vuister, Zhu, Pfeifer and Bax 4 peak picking Sparky Goddard