☰ Navigation Tabs
Cryo-EM of the GTP-bound human dynamin-1 polymer assembled on the membrane in the super constricted state
Sample GTP-bound human dynamin helical polymer encased around phosphatidylserine lipid bilayer membrane tube
Specimen Preparation Sample Aggregation State HELICAL ARRAY Vitrification Instrument Cryogen Name ETHANE Sample Vitrification Details
3D Reconstruction Reconstruction Method HELICAL Number of Particles 14322 Reported Resolution (Å) 10.1 Resolution Method FSC 0.143 CUT-OFF Other Details Refinement Type Symmetry Type HELICAL Axial Symmetry C1 Axial Rise 14.63 Angular Rotation 26.14
Data Acquisition Detector Type GATAN K2 SUMMIT (4k x 4k) Electron Dose (electrons/Å**2) 36
Imaging Experiment 1 Date of Experiment Temperature (Kelvin) Microscope Model FEI TECNAI 20 Minimum Defocus (nm) Maximum Defocus (nm) Minimum Tilt Angle (degrees) Maximum Tilt Angle (degrees) Nominal CS Imaging Mode BRIGHT FIELD Specimen Holder Model Nominal Magnification Calibrated Magnification Source FIELD EMISSION GUN Acceleration Voltage (kV) 200 Imaging Details
Image Processing CTF Correction Type CTF Correction Details Number of Particles Selected Particle Selection Details PHASE FLIPPING AND AMPLITUDE CORRECTION