☰ Navigation Tabs
Crystal structure of Certolizumab Fab
Crystallization Crystalization Experiments ID Method pH Temperature Details 1 VAPOR DIFFUSION, HANGING DROP 293 0.1M bis-Tris pH5.5, 0.2M Ammunium sulfate, 25% PEG3350
Crystal Properties Matthews coefficient Solvent content 3.17 61.17
Crystal Data Unit Cell Length ( Å ) Angle ( ˚ ) a = 58.33 α = 90 b = 63.696 β = 90 c = 161.415 γ = 90
Symmetry Space Group P 21 21 21
Diffraction Diffraction Experiment ID # Crystal ID Scattering Type Data Collection Temperature Detector Detector Type Details Collection Date Monochromator Protocol 1 1 x-ray 100 CCD ADSC QUANTUM 315r 2015-04-08 M SINGLE WAVELENGTH
Radiation Source ID # Source Type Wavelength List Synchrotron Site Beamline 1 SYNCHROTRON PAL/PLS BEAMLINE 5C (4A) 1.00 PAL/PLS 5C (4A)
Data Collection Overall ID # Resolution (High) Resolution (Low) Percent Possible (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot 1 1.95 37.96 98.2 28.2 5.9 43749
Refinement Statistics Diffraction ID Structure Solution Method Cross Validation method Resolution (High) Resolution (Low) Cut-off Sigma (F) Number Reflections (Observed) Number Reflections (R-Free) Percent Reflections (Observed) R-Factor (Observed) R-Work (Depositor) R-Work (DCC) R-Free (Depositor) R-Free (DCC) Mean Isotropic B X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.952 29.165 1.34 43749 2193 98.2 0.1492 0.1477 0.1516 0.1787 0.18
Temperature Factor Modeling Anisotropic B[1][1] Anisotropic B[1][2] Anisotropic B[1][3] Anisotropic B[2][2] Anisotropic B[2][3] Anisotropic B[3][3]
RMS Deviations Key Refinement Restraint Deviation f_dihedral_angle_d 12.927 f_angle_d 1.06 f_chiral_restr 0.044 f_bond_d 0.007 f_plane_restr 0.005
Non-Hydrogen Atoms Used in Refinement Non-Hydrogen Atoms Number Protein Atoms 3290 Nucleic Acid Atoms Solvent Atoms 607 Heterogen Atoms
Software Software Software Name Purpose PHENIX refinement HKL-2000 data reduction HKL-2000 data scaling PHASER phasing