2JZY

Solution structure of C-terminal effector domain of putative two-component-system response regulator involved in copper resistance from Klebsiella pneumoniae


SOLUTION NMR
NMR Experiment
ExperimentTypeSample ContentsSolventIonic StrengthpHPressureTemperature (K)Spectrometer
13D HNCA1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
23D HN(CO)CA1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
33D CBCA(CO)NH1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
43D HNCACB1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
53D HBHA(CO)NH1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
63D 1H-15N NOESY1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
73D HNCO1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
83D HCACO1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
93D 1H-13C NOESY1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
103D HCCH-TOCSY1 mM [U-13C; U-15N] C-terminal domain of TCS response regulator, 20 mM Tris, 150 mM NaCl, 150 mM Glu, 150 mM Arg90% H2O/10% D2O150mM NaCl and 150mM Glu/Arg.7.5ambient293
NMR Spectrometer Information
SpectrometerManufacturerModelField Strength
1BrukerAVANCE500
2BrukerDRX600
NMR Refinement
MethodDetailsSoftware
distance geometry, simulated annealing, torsion angle dynamicsCYANA
NMR Ensemble Information
Conformer Selection Criteriatarget function
Conformers Calculated Total Number100
Conformers Submitted Total Number20
Representative Model1 (lowest energy)
Computation: NMR Software
#ClassificationVersionSoftware NameAuthor
1refinementCYANA2.1Guntert, Mumenthaler and Wuthrich