27PY | pdb_000027py

Dictyostelium discoideum cytoplasmic dynein motor domain in the presence of ADP (ADP state 1)


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 3VKG 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d5.775
f_angle_d0.496
f_chiral_restr0.038
f_plane_restr0.004
f_bond_d0.002
Sample
Dictyostelium discoideum HF380 cytoplasmic dynein motor domain in the presence of ADP
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles2128136
Reported Resolution (Å)2.61
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsThe selected particles were refined by non-uniform refinement in cryoSPARC.
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (3VKG)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement TargetReal-space target; weighted map sum at atom centers
Overall B Value109.2
Fitting Procedure
DetailsA monomeric HF380 motor-domain model was fitted into the cryo-EM map and refined by phenix.real_space_refine.
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)80
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelJEOL CRYO ARM 300
Minimum Defocus (nm)700
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelJEOL CRYOSPECPORTER
Nominal Magnification60000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.4.1
IMAGE ACQUISITIONSerialEM3.8 or 4.050
CTF CORRECTIONcryoSPARC4.4.1
MODEL FITTINGUCSF ChimeraX1.7
MODEL FITTINGCoot0.9.8.92
MODEL REFINEMENTPHENIX1.21_5207
INITIAL EULER ASSIGNMENTcryoSPARC4.4.1
FINAL EULER ASSIGNMENTcryoSPARC4.4.1
CLASSIFICATIONcryoSPARC4.4.1
RECONSTRUCTIONcryoSPARC4.4.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTIONCTF parameters were estimated using Patch CTF estimation in cryoSPARC and further refined by global and local CTF refinement.4072620Particles were selected by blob picking and template-based picking in cryoSPARC, followed by 2D classification and 3D refinement to retain 4,072,620 particles for 3D variability analysis.