☰ Navigation Tabs
IC3 of CB1 (L431A,A432L) Bound to G(alpha)i
NMR Experiment Experiment Type Sample Contents Solvent Ionic Strength pH Pressure Temperature (K) Spectrometer 1 2D NOESY ALKT 4.0 mM
G(alpha)i 200 uM acetate buffer, 10 mM 10 mM acetate buffer 6.0 1 atm 308 2 2D TOCSY ALKT 4.0 mM
G(alpha)i 200 uM acetate buffer, 10 mM 10 mM acetate buffer 6.0 1 atm 308
NMR Spectrometer Information Spectrometer Manufacturer Model Field Strength 1 Bruker AVANCE 600
NMR Refinement Method Details Software metric matrix distance geometry to generate initial ensemble of structures; 20 lowest penalty structures used for ensemble-based IRMA refinement Felix
NMR Ensemble Information Conformer Selection Criteria back calculated data agree with experimental NOESY spectrum Conformers Calculated Total Number 20 Conformers Submitted Total Number 1
Additional NMR Experimental Information Details transferred NOEs, build up rates from 6 mixing times
Computation: NMR Software # Classification Version Software Name Author 1 data analysis Felix msi 95 hare 2 refinement DGII home written havel 3 iterative matrix relaxation IRMA 2 Boelens